[en] Preanalytical conditions applied during sample collection and processing can affect the detection or quantification of unstable phosphoprotein biomarkers. We evaluated the consequences of tissue stabilization and protein extraction methods on phosphoprotein analysis. The effects of stabilization techniques (heat stabilization, snap-freezing) and time on the levels of phosphoproteins, including phospho-Akt, p-ERK 1/2, p-IkBα, p-JNK, and p38 MAPK, were evaluated using a BioPlex phosphoprotein assay. Additionally, two different protein extraction protocols, using different extraction buffers (8 M urea buffer, or Bio-Rad buffer without urea) were tested. For snap-frozen samples, protein extraction yields were comparable with the two buffer systems. For heat-stabilized samples, total protein yields were significantly lower following extraction in non-urea buffer. However, the concentrations of specific phosphoproteins were significantly higher in heat-stabilized samples than in the corresponding snap-frozen samples, indicating that this tissue processing method better preserved phosphoproteins. Significant differences were found between the measured phosphoprotein levels in heat-stabilized and snap-frozen tissue, suggesting that alterations occur very rapidly after tissue excision. Our results suggest that heat stabilization can be used as a tissue processing method for subsequent phosphoprotein analyses, but also suggest that the BioPlex phosphoprotein assay could be used as a possible quality control method to assess tissue sample integrity.
Disciplines :
Oncologie
Auteur, co-auteur :
Kofanova, Olga A; 1 Integrated BioBank of Luxembourg (IBBL) , Luxembourg .
Fack, Fred
NICLOU, Simone P. ; Laboratoire NorLux de Neuro-Oncologie, Department of Oncology, Centre de Recherche Public de la Santé (CRP Santé), Luxembourg.
BETSOU, Fay ; Integrated BioBank of Luxembourg (IBBL), Luxembourg
Co-auteurs externes :
yes
Langue du document :
Anglais
Titre :
Combined effect of tissue stabilization and protein extraction methods on phosphoprotein analysis.
Schtilbans V, Wu M, Burstein DE. Current overview of the role of Akt in cancer studies via applied immunohistochemistry. Ann Diagn Pathol 2008;12:153-160
Andersen JN, Sathyanarayanan S, Di Bacco A, et al. Pathwaybased identification of biomarkers for targeted therapeutics: Personalized oncology with PI3K pathway inhibitors. Sci Transl Med 2010;2:43-55
Niclou SP, Fack F, Rajcevic U. Glioma proteomics: Status and perspectives. J Proteomics 2010;73:1823-1838
Espina V, Edmiston KH, Heiby M, et al. A portrait of tissue phosphoprotein stability in the clinical tissue procurement process. Mol Cell Proteom 1998;7:1998-2018
Baker AF, Dragovich T, Ihle NT, et al. Stability of phosphoprotein as a biological marker of tumor signaling. Clin Cancer Res 2005;11:4338-4340
Holzer TR, Fulford AD, Arkins AM, et al. Ischemic time impacts biological integrity of phosphor-proteins in PI3K/Akt, Erk/MAPK, and p38 MAPK signaling networks. Anticancer Res 2011; 31:2073-2081
Betsou F, Gunter E, Clements J, et al. Identification of evidencebased biospecimen quality control tools. J Mol Diagnostics 2013, 15:3-16
Montero C. The antigen-antibody reaction in immunohistochemistry. J Histochem Cytochem 2003;51:1-4
Hayat MA. Fixation and embedding. In: Microscopy, Immunohistochemistry, and Antigen Retrieval Methods for Light and Electron Microscopy, ed. Hayat MA, Kluwer Academic, New York, NY; 2002, pp 71-93
Ramos-Vara JA. Technical aspects of immunohistochemistry. Vet Pathol 2005;42:405-426
Mueller C, Edminton KH, Carpenter C, et al. One-step preservation of phosphoproteins and tissue morphology at room temperature for diagnostic and research specimens. PLoS One 2011;6:23780
Svensson M, Boren M, Sko? ld K, et al. Heat stabilization of the tissue proteome: A new technology for improved proteomics. J Proteome Res 2009;8:974-981
Boren M. Methodology and technology for stabilization of specific states of signal transduction proteins. Methods Mol Biology 2011;717:91-100
Gao Q, Simonyi K, Suen C, et al. Simultaneous detection of 12 phosphorylated and 7 total proteins using the Bio-Plex suspension array system. Bio-Rad Bull 2981 2004
Rountree CB, Van Kirk CA, You H, et al. Clinical application for the preservation of phosphor-proteins through in-situ tissue stabilization. Proteome Sci 2010;8:61
Sko? ld K, Svensson M, Norrman M, et al. The significance of biochemical and molecular sample integrity in brain proteomics and peptidomics: Stathmin 2-20 and peptides as sample quality indicators. Proteomics 2007;7:4445-4456