Article (Périodiques scientifiques)
Comparison of beamformers for EEG source signal reconstruction
Jonmohamadi, Yaqub; Poudel; Innes, Carrie et al.
2014In Biomedical Signal Processing and Control, 14, p. 175-188
Peer reviewed vérifié par ORBi
 

Documents


Texte intégral
Jonmohamadi - Comparison of beamformers on EEG source signal reconstruction (Biomed Sig Proc Control. 2014).pdf
Postprint Éditeur (3.71 MB)
Demander un accès

Tous les documents dans ORBilu sont protégés par une licence d'utilisation.

Envoyer vers



Détails



Mots-clés :
Beamformer; EEG; Gain; Region of interest (ROI); Signal-to-noise power ratio (SNR); Time-course reconstruction
Résumé :
[en] Recently, several new beamformers have been introduced for reconstruction and localization of neural sources from EEG and MEG.Although studies have compared the accuracy of beamformers for localization of strong sources in the brain, a comparison of new and conventional beamformers for time-course reconstruction of a desired source has not been previously undertaken. In this study, 8 beamformers were examined with respectto several parameters, including variations in depth, orientation, magnitude, and frequency of the simulated source to determine their (i) effectiveness at time-course reconstruction of the sources, and (ii) stability of their performances with respect to the input changes. The spatial and directional pass-bands of the beamformers were estimated via simulated and real EEG sources to determine spatial resolution. White-noise spatial maps of the beamformers were calculated to show which beamformers have a location bias. Simulated EEG data were produced by projection via forward head modelling of simulated sources onto scalp electrodes, then superimposed on real background EEG. Real EEG was recorded from a patient with essential tremor and deep brain implanted electrodes. Gain – the ratio of SNR of the reconstructed time-course to the input SNR – was the primary measure of performance of the beamformers. Overall, minimum-variance beamformers had higher Gains and superior spatial resolution to those of the minimum-norm beamformers, although their performance was more sensitive to changes in magnitude, depth, and frequency of the simulated source. White-noise spatial maps showed that several, but not all, beamformers have an undesirable location bias.
Centre de recherche :
- Luxembourg Centre for Systems Biomedicine (LCSB): Clinical & Experimental Neuroscience (Krüger Group)
Disciplines :
Génétique & processus génétiques
Auteur, co-auteur :
Jonmohamadi, Yaqub
Poudel
Innes, Carrie
Weiss, Daniel
KRÜGER, Rejko ;  University of Luxembourg > Faculty of Science, Technology and Communication (FSTC) > Life Science Research Unit
Jones, Richard
Co-auteurs externes :
yes
Langue du document :
Anglais
Titre :
Comparison of beamformers for EEG source signal reconstruction
Date de publication/diffusion :
novembre 2014
Titre du périodique :
Biomedical Signal Processing and Control
ISSN :
1746-8094
eISSN :
1746-8108
Maison d'édition :
Elsevier, Amsterdam, Pays-Bas
Volume/Tome :
14
Pagination :
175-188
Peer reviewed :
Peer reviewed vérifié par ORBi
Disponible sur ORBilu :
depuis le 13 novembre 2014

Statistiques


Nombre de vues
196 (dont 10 Unilu)
Nombre de téléchargements
3 (dont 3 Unilu)

citations Scopus®
 
33
citations Scopus®
sans auto-citations
29
OpenCitations
 
25
citations OpenAlex
 
37
citations WoS
 
31

Bibliographie


Publications similaires



Contacter ORBilu