Abstract :
[en] Recently, several new beamformers have been introduced for reconstruction and localization of neural sources from EEG and MEG.Although studies have compared the accuracy of beamformers for localization of strong sources in the brain, a comparison of new and conventional beamformers for time-course reconstruction of a desired source has not been previously undertaken. In this study, 8 beamformers were examined with respectto several parameters, including variations in depth, orientation, magnitude, and frequency of the simulated source to determine their (i) effectiveness at time-course reconstruction of the sources, and (ii) stability of their performances with respect to the input changes. The spatial and directional pass-bands of the beamformers were estimated via simulated and real EEG sources to determine spatial resolution. White-noise spatial maps of the beamformers were calculated to show which beamformers have a location bias. Simulated EEG data were produced by projection via forward head modelling of simulated sources onto scalp electrodes, then superimposed on real background EEG. Real EEG was recorded from a patient with essential tremor and deep brain implanted electrodes. Gain – the ratio of SNR of the reconstructed time-course to the input SNR – was the primary measure of performance of the beamformers. Overall, minimum-variance beamformers had higher Gains and superior spatial resolution to those of the minimum-norm beamformers, although their performance was more sensitive to changes in magnitude, depth, and frequency of the simulated source. White-noise spatial maps showed that several, but not all, beamformers have an undesirable location bias.
Research center :
- Luxembourg Centre for Systems Biomedicine (LCSB): Clinical & Experimental Neuroscience (Krüger Group)
Disciplines :
Genetics & genetic processes
Author, co-author :
Jonmohamadi, Yaqub
Poudel
Innes, Carrie
Weiss, Daniel
KRÜGER, Rejko ;  University of Luxembourg > Faculty of Science, Technology and Communication (FSTC) > Life Science Research Unit
Jones, Richard
External co-authors :
yes
Language :
English
Title :
Comparison of beamformers for EEG source signal reconstruction
Publication date :
November 2014
Journal title :
Biomedical Signal Processing and Control
ISSN :
1746-8094
eISSN :
1746-8108
Publisher :
Elsevier, Amsterdam, Netherlands
Volume :
14
Pages :
175-188
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBilu :
since 13 November 2014

Statistics


Number of views
192 (10 by Unilu)
Number of downloads
3 (3 by Unilu)

Scopus citations®
 
33
Scopus citations®
without self-citations
29
OpenCitations
 
25
OpenAlex citations
 
37
WoS citations
 
31

Bibliography


Similar publications



Contact ORBilu