Numerical comparative study of five currently used implants for high tibial osteotomy: realistic loading including muscle forces versus simplified experimental loading
DIFFO KAZE, Arnaud; MAAS, Stefan; KEDZIORA, Slawomir et al.
2017In Journal of Experimental Orthopaedics, 5 (28)
Peer reviewed vérifié par ORBi
 

Documents


Texte intégral
DiffoKaze_et_al_2017.pdf
Postprint Éditeur (4.37 MB)
Demander un accès

Tous les documents dans ORBilu sont protégés par une licence d'utilisation.

Envoyer vers



Détails



Mots-clés :
Finite element; Musculoskeletal model; Lower limb; Stance phase; Medial open wedge HTO; iBalance; Contour lock; PEEKPower; TomoFix; Section forces
Résumé :
[en] Background Many different fixation devices are used to maintain the correction angle after medial open wedge high tibial osteotomy (MOWHTO). Each device must provide at least sufficient mechanical stability to avoid loss of correction and unwanted fracture of the contralateral cortex until the bone heals. In the present study, the mechanical stability of following different implants was compared: the TomoFix small stature (sm), the TomoFix standard (std), the Contour Lock, the iBalance and the second generation PEEKPower. Simplified loading, usually consisting of a vertical load applied to the tibia plateau, is used for experimental testing of fixation devices and also in numerical studies. Therefore, this study additionally compared this simplified experimental loading with a more realistic loading that includes the muscle forces. Method Two types of finite element models, according to the considered loading, were created. The first type numerically simulated the static tests of MOWHTO implants performed in a previous experimental biomechanical study, by applying a vertical compressive load perpendicularly to the plateau of the osteotomized tibia. The second type included muscle forces in finite element models of the lower limb with osteotomized tibiae and simulated the stance phase of normal gait. Section forces in the models were determined and compared. Stresses in the implants and contralateral cortex, and micromovements of the osteotomy wedge, were calculated. Results For both loading types, the stresses in the implants were lower than the threshold values defined by the material strength. The stresses in the lateral cortex were smaller than the ultimate tensile strength of the cortical bone. The implants iBalance and Contour Lock allowed the smallest micromovements of the wedge, while the PEEKPower allowed the highest. There was a correlation between the micromovements of the wedge, obtained for the simplified loading of the tibia, and the more realistic loading of the lower limb at 15% of the gait cycle (Pearson’s value r = 0.982). Conclusions An axial compressive load applied perpendicularly to the tibia plateau, with a magnitude equal to the first peak value of the knee joint contact forces, corresponds quite well to a realistic loading of the tibia during the stance phase of normal gait (at 15% of the gait cycle and a knee flexion of about 22 degrees). However, this magnitude of the knee joint contact forces overloads the tibia compared to more realistic calculations, where the muscle forces are considered. The iBalance and Contour Lock implants provide higher rigidity to the bone-implant constructs compared to the TomoFix and the PEEKPower plates.
Disciplines :
Ingénierie mécanique
Auteur, co-auteur :
DIFFO KAZE, Arnaud ;  University of Luxembourg > Faculty of Science, Technology and Communication (FSTC) > Engineering Research Unit
MAAS, Stefan ;  University of Luxembourg > Faculty of Science, Technology and Communication (FSTC) > Engineering Research Unit
KEDZIORA, Slawomir  ;  University of Luxembourg > Faculty of Science, Technology and Communication (FSTC) > Engineering Research Unit
Belsey, James
Haupert
WOLF, Claude  ;  University of Luxembourg > Faculty of Science, Technology and Communication (FSTC) > Engineering Research Unit
Hoffmann, Alexander
Pape, Dietrich
Co-auteurs externes :
yes
Langue du document :
Anglais
Titre :
Numerical comparative study of five currently used implants for high tibial osteotomy: realistic loading including muscle forces versus simplified experimental loading
Date de publication/diffusion :
06 novembre 2017
Titre du périodique :
Journal of Experimental Orthopaedics
eISSN :
2197-1153
Maison d'édition :
Springer International Publishing A.G., Heidelberg, Suisse
Volume/Tome :
5
Fascicule/Saison :
28
Peer reviewed :
Peer reviewed vérifié par ORBi
Disponible sur ORBilu :
depuis le 29 mars 2019

Statistiques


Nombre de vues
207 (dont 19 Unilu)
Nombre de téléchargements
0 (dont 0 Unilu)

citations Scopus®
 
7
citations Scopus®
sans auto-citations
6
OpenCitations
 
2
citations OpenAlex
 
7

Bibliographie


Publications similaires



Contacter ORBilu