[en] Due to the demand for sustainable buildings and slim constructions, composite slim-floor systems become more important. The present European Codes do not include complete de-sign rules for shallow-floor beams. Therefore, the objective of the recent research work was concentrated on the development of additional regulations, considering ultimate limit state, serviceability limit state and fire design. Apart from traditional sections consisting of rolled profiles also floor-slabs with integrated steel-box-sections have been considered
Disciplines :
Ingénierie civile
Auteur, co-auteur :
SCHÄFER, Markus ; University of Luxembourg > Faculty of Science, Technology and Communication (FSTC) > Engineering Research Unit
Co-auteurs externes :
no
Langue du document :
Anglais
Titre :
Review of plastic moment resistance for compsite beams - Development of second generation of Eurocode 4
Date de publication/diffusion :
30 juillet 2017
Nom de la manifestation :
8th International Conference on Composite Structures in Steel and Concrete
Organisateur de la manifestation :
Virginia Tech
Lieu de la manifestation :
Jackson Hole, Wyoming, Etats-Unis
Date de la manifestation :
30-07-2017 to 02-08-2017
Sur invitation :
Oui
Manifestation à portée :
International
Titre de l'ouvrage principal :
8th International Conference on Composie Structures in Steel and Concrete