Article (Scientific journals)
Use of the Heartrail II catheter as a distal stent delivery device; an extended case series.
Mamas, Mamas A.; Eichhofer, Jonas; Hendry, Cara et al.
2009In EuroIntervention: Journal of EuroPCR in Collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 5 (2), p. 265-71
Peer Reviewed verified by ORBi
 

Files


Full Text
Use of the Heartrail II catheter as a distal stent delivery device.pdf
Publisher postprint (448.35 kB)
Download

All documents in ORBilu are protected by a user license.

Send to



Details



Keywords :
Adult; Aged; Aged, 80 and over; Angioplasty, Balloon, Coronary/adverse effects/instrumentation; Cardiac Catheterization/adverse effects/instrumentation; Coronary Angiography; Coronary Stenosis/radiography/therapy; Equipment Design; Female; Graft Occlusion, Vascular/radiography/therapy; Humans; Male; Middle Aged; Prospective Studies; Stents; Treatment Outcome
Abstract :
[en] AIMS: The Terumo Heartrail catheter (Terumo Corp., Tokyo, Japan) allows extra deep catheter intubation of coronary vessels and has been shown to be useful in CTO lesions. The aim of this study is to assess the safety and efficacy of using the Heartrail II catheter as a distal stent delivery system in PCI following failure of conventional techniques. METHODS AND RESULTS: We prospectively identified cases performed over a 15-month period in which a Heartrail catheter was used to facilitate stent delivery following failure of conventional techniques. Stent delivery using the Heartrail catheter was performed in 35 cases and was successful in 31 cases. Success rates of 100% in grafts, 95% in RCA, 80% in LAD and 60% in circumflex cases were recorded respectively. Successful stent delivery was associated with intubation depth, with 29/29 succeeding when the intubation depth was > 2 cm and failure in 4/5 cases when the intubation depth <or= 2 cm. There were no complications related to deep intubation of the catheter. CONCLUSIONS: Use of the Heartrail catheter is safe and highly effective for aiding stent delivery across proximal obstructions in both left and right coronary systems. The small number of unsuccessful cases were related to inability of the catheter to traverse stenotic proximal obstructions within 2 cm of the RCA and LCA origins.
Disciplines :
Cardiovascular & respiratory systems
Author, co-author :
Mamas, Mamas A.
Eichhofer, Jonas
Hendry, Cara
El-Omar, Magdi
Clarke, Bernard
NEYSES, Ludwig ;  University of Luxembourg > Research Office
Fath-Ordoubadi, Farzin
Fraser, Doug
External co-authors :
yes
Language :
English
Title :
Use of the Heartrail II catheter as a distal stent delivery device; an extended case series.
Publication date :
2009
Journal title :
EuroIntervention: Journal of EuroPCR in Collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology
ISSN :
1774-024X
eISSN :
1969-6213
Publisher :
Société Europa Edition, Toulouse, France
Volume :
5
Issue :
2
Pages :
265-71
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBilu :
since 04 July 2016

Statistics


Number of views
143 (0 by Unilu)
Number of downloads
198 (0 by Unilu)

Scopus citations®
 
42
Scopus citations®
without self-citations
33
OpenAlex citations
 
33
WoS citations
 
34

Bibliography