Article (Périodiques scientifiques)
Use of the Heartrail II catheter as a distal stent delivery device; an extended case series.
Mamas, Mamas A.; Eichhofer, Jonas; Hendry, Cara et al.
2009In EuroIntervention: Journal of EuroPCR in Collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 5 (2), p. 265-71
Peer reviewed vérifié par ORBi
 

Documents


Texte intégral
Use of the Heartrail II catheter as a distal stent delivery device.pdf
Postprint Éditeur (448.35 kB)
Télécharger

Tous les documents dans ORBilu sont protégés par une licence d'utilisation.

Envoyer vers



Détails



Mots-clés :
Adult; Aged; Aged, 80 and over; Angioplasty, Balloon, Coronary/adverse effects/instrumentation; Cardiac Catheterization/adverse effects/instrumentation; Coronary Angiography; Coronary Stenosis/radiography/therapy; Equipment Design; Female; Graft Occlusion, Vascular/radiography/therapy; Humans; Male; Middle Aged; Prospective Studies; Stents; Treatment Outcome
Résumé :
[en] AIMS: The Terumo Heartrail catheter (Terumo Corp., Tokyo, Japan) allows extra deep catheter intubation of coronary vessels and has been shown to be useful in CTO lesions. The aim of this study is to assess the safety and efficacy of using the Heartrail II catheter as a distal stent delivery system in PCI following failure of conventional techniques. METHODS AND RESULTS: We prospectively identified cases performed over a 15-month period in which a Heartrail catheter was used to facilitate stent delivery following failure of conventional techniques. Stent delivery using the Heartrail catheter was performed in 35 cases and was successful in 31 cases. Success rates of 100% in grafts, 95% in RCA, 80% in LAD and 60% in circumflex cases were recorded respectively. Successful stent delivery was associated with intubation depth, with 29/29 succeeding when the intubation depth was > 2 cm and failure in 4/5 cases when the intubation depth <or= 2 cm. There were no complications related to deep intubation of the catheter. CONCLUSIONS: Use of the Heartrail catheter is safe and highly effective for aiding stent delivery across proximal obstructions in both left and right coronary systems. The small number of unsuccessful cases were related to inability of the catheter to traverse stenotic proximal obstructions within 2 cm of the RCA and LCA origins.
Disciplines :
Systèmes cardiovasculaire & respiratoire
Auteur, co-auteur :
Mamas, Mamas A.
Eichhofer, Jonas
Hendry, Cara
El-Omar, Magdi
Clarke, Bernard
NEYSES, Ludwig ;  University of Luxembourg > Research Office
Fath-Ordoubadi, Farzin
Fraser, Doug
Co-auteurs externes :
yes
Langue du document :
Anglais
Titre :
Use of the Heartrail II catheter as a distal stent delivery device; an extended case series.
Date de publication/diffusion :
2009
Titre du périodique :
EuroIntervention: Journal of EuroPCR in Collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology
ISSN :
1774-024X
eISSN :
1969-6213
Maison d'édition :
Société Europa Edition, Toulouse, France
Volume/Tome :
5
Fascicule/Saison :
2
Pagination :
265-71
Peer reviewed :
Peer reviewed vérifié par ORBi
Disponible sur ORBilu :
depuis le 04 juillet 2016

Statistiques


Nombre de vues
144 (dont 0 Unilu)
Nombre de téléchargements
198 (dont 0 Unilu)

citations Scopus®
 
42
citations Scopus®
sans auto-citations
33
citations OpenAlex
 
33
citations WoS
 
34

Bibliographie


Publications similaires



Contacter ORBilu