[en] The highest transparency in glass façades is obtained with point fitted glass units. Point fitted insulating glass units minimize thermal bridging and lead to glass façades with better energy efficiency. Though, insufficient knowledge is present to offer a design method for point fittings in insulating glass. Therefore research has been carried out to extend the existing SLG-design-method of Beyer for point fitted single and laminated glass to insulation glass units. This paper presents first results of this research campaign. Load bearing tests on point fittings in single glazing have been conducted. An FEA-model of the point fitting is calibrated by the test data according to the method of Kasper. By means of this verified FEA-model, the influence on the stress peak at the borehole of the edge distance of the point fitting as well as the edge bond is investigated. In addition, the size of the so called “local area” is adjusted for insulation glass units.
Disciplines :
Ingénierie civile
Auteur, co-auteur :
TIBOLT, Mike ; University of Luxembourg > Faculty of Science, Technology and Communication (FSTC) > Engineering Research Unit
ODENBREIT, Christoph ; University of Luxembourg > Faculty of Science, Technology and Communication (FSTC) > Engineering Research Unit
HECHLER, Oliver ; University of Luxembourg > Faculty of Science, Technology and Communication (FSTC) > Engineering Research Unit
Co-auteurs externes :
yes
Langue du document :
Anglais
Titre :
Numerical investigation of insulation glass units with undercut point fittings. (LAC13.D)
Date de publication/diffusion :
avril 2013
Nom de la manifestation :
European COST Action TU0905 - Mid-term conference on structural glass
Beyer, J. 2007. Ein Beitrag zum Bemessungskonzept für punktgestützte Glastafeln. Darmstadt: TU Darmstadt.
Dias V., Hechler O., Odenbreit C., Scholzen F. & Ben Zineb T. 2012. Numerical investigations of structural adhesive connections. Engineered Transparency, GlassTech 2012. Düsseldorf.
DIN 18008-3. 2011. Glas im Bauwesen - Bemessungs- und Konstruktionsregeln- Teil 3: Punktförmig gelagerte Verglasung. Berlin: Deutsches Institut für Normung.
Feldmeier F. 2006. Klimabelastung und Lastverteilung bei Mehrscheiben-Isolierglas. Stahlbau 75, Issue 6, Pages 467-478, Ernst & Sohn Verlag, Berlin.
Hechler O., Dias V., Tibolt M. & Odenbreit C. 2012. Design concept for point fitting of insulation glass units. VI International Congress on Architectural Envelopes (ICAE). San Sebastian.
Tibolt M. Investigations in discrete connections between insulating glass and steel for energy efficient and transparent building envelopes. Dissertation. University of Luxembourg. Not yet published
Tibolt M., Hechler, O. & Odenbreit, C. 2013. Experimental investigations and numerical modeling of point fitted glass panes. 2nd International Conference on Structures and Architecture ICSA. Guimaraes. Not yet published.
Z-70.2-122. 2007. Punktgehaltene Verglasung mit fischer Zykon Punkthaltern (FZP-G-Z). Allgemeine bauaufsichtliche Zulassung, Deutschen Instituts für Bautechnik (DIBT). Berlin, 2007.