See detailAnodal tDCS modulates cortical activity and synchronization in Parkinson's disease depending on motor processing.
Schoellmann, Anna; Scholten, Marlieke; Wasserka, Barbara et al

in NeuroImage: Clinical (2019), 22

BACKGROUND: Transcranial direct current stimulation (tDCS) may alleviate motor symptoms in Parkinson's disease (PD). However, the neurophysiological effects of tDCS on cortical activation, synchronization ... [more ▼]

BACKGROUND: Transcranial direct current stimulation (tDCS) may alleviate motor symptoms in Parkinson's disease (PD). However, the neurophysiological effects of tDCS on cortical activation, synchronization, and the relation to clinical motor symptoms and motor integration need characterization. OBJECTIVE: We aimed to explore the effect of tDCS over the left sensorimotor area on clinical motor outcome, right hand fine motor performance as well as cortical activity and synchronization in the high beta range. METHODS: In this double-blind randomized sham-controlled clinico-neurophysiological study we investigated ten idiopathic PD patients and eleven matched healthy controls (HC) on two days during an isometric precision grip task and at rest before and after 'verum' and 'sham' anodal tDCS (20min; 1mA; anode [C3], cathode [Fp2]). We measured clinical outcome, fine motor performance, and analysed both cortical frequency domain activity and corticocortical imaginary coherence. RESULTS: tDCS improved PD motor symptoms. Neurophysiological features indicated a motor-task-specific modulation of activity and coherence from 22 to 27Hz after 'verum' stimulation in PD. Activity was significantly reduced over the left sensorimotor and right frontotemporal area. Before stimulation, PD patients showed reduced coherence over the left sensorimotor area during motor task compared to HC, and this increased after 'verum' stimulation in the motor task. The activity and synchronization modulation were neither observed at rest, after sham stimulation nor in healthy controls. CONCLUSION: Verum tDCS modulated the PD cortical network specifically during fine motor integration. Cortical oscillatory features were not in general deregulated in PD, but depended on motor processing. [less ▲]

Detailed reference viewed: 169 (5 UL)
Full Text
Peer Reviewed
See detailPaCER - A fully automated method for electrode trajectory and contact reconstruction in deep brain stimulation
Husch, Andreas UL; Petersen, Mikkel V.; Gemmar, Peter et al

in NeuroImage: Clinical (2018), 17

Abstract Deep brain stimulation (DBS) is a neurosurgical intervention where electrodes are permanently implanted into the brain in order to modulate pathologic neural activity. The post-operative ... [more ▼]

Abstract Deep brain stimulation (DBS) is a neurosurgical intervention where electrodes are permanently implanted into the brain in order to modulate pathologic neural activity. The post-operative reconstruction of the DBS electrodes is important for an efficient stimulation parameter tuning. A major limitation of existing approaches for electrode reconstruction from post-operative imaging that prevents the clinical routine use is that they are manual or semi-automatic, and thus both time-consuming and subjective. Moreover, the existing methods rely on a simplified model of a straight line electrode trajectory, rather than the more realistic curved trajectory. The main contribution of this paper is that for the first time we present a highly accurate and fully automated method for electrode reconstruction that considers curved trajectories. The robustness of our proposed method is demonstrated using a multi-center clinical dataset consisting of N=44 electrodes. In all cases the electrode trajectories were successfully identified and reconstructed. In addition, the accuracy is demonstrated quantitatively using a high-accuracy phantom with known ground truth. In the phantom experiment, the method could detect individual electrode contacts with high accuracy and the trajectory reconstruction reached an error level below 100 μm (0.046 ± 0.025 mm). An implementation of the method is made publicly available such that it can directly be used by researchers or clinicians. This constitutes an important step towards future integration of lead reconstruction into standard clinical care. [less ▲]

Detailed reference viewed: 234 (30 UL)