![]() ![]() ; ; et al in Toxicology in vitro : an international journal published in association with BIBRA (2014), 28(1), 104-12 Predictive in vitro models alternative to in vivo animal will have a significant impact in toxicology. Conventional 2D models do not reflect the complexity of a 3D organ resulting in discrepancies between ... [more ▼] Predictive in vitro models alternative to in vivo animal will have a significant impact in toxicology. Conventional 2D models do not reflect the complexity of a 3D organ resulting in discrepancies between experimental in vitro and in vivo data. Using 3D HepaRG organotypic cultures we tested four drugs (aflatoxin B1, amiodarone, valproic acid and chlorpromazine) for toxic effects and compared the results with 2D HepaRG and HepG2 cultures. We show that 3D HepaRG cultures are more sensitive than the other tested cultures to aflatoxin B1 which is only toxic upon metabolic activation in the liver. We observed that CYP3A4 activity is higher in the 3D HepaRG cultures compared to the 2D HepaRG cultures. Furthermore, we investigated repeated dose toxicity of chlorpromazine and assessed its effects on glucose and lactate metabolism. Sub-toxic concentrations of chlorpromazine induced significant metabolic changes in both 2D and 3D HepaRG cultures upon acute and repeated dose (3 doses) exposure. In summary, our data support the hypothesis that 3D cell culture models better mimic the in vivo tissue and improve cellular functionality. The 3D HepaRG organotypic cultures represent a high throughput system for drug toxicity screening. This system is therefore a promising tool in preclinical testing of human relevance which can allow reducing and/or replacing animal testing for drug adverse effects. [less ▲] Detailed reference viewed: 119 (0 UL)![]() ![]() ; Noor, Fozia ![]() in Toxicology in vitro : an international journal published in association with BIBRA (2010), 24(2), 686-94 A dynamic respiration assay based on luminescence decay time detection of oxygen for high throughput toxicological assessment is presented. The method uses 24-well plates (OxoDishes) read with the help of ... [more ▼] A dynamic respiration assay based on luminescence decay time detection of oxygen for high throughput toxicological assessment is presented. The method uses 24-well plates (OxoDishes) read with the help of a sensor dish reader placed in a humidified CO(2)-incubator. Adherent primary rat hepatocytes and the human hepatic cell line Hep G2 were exposed to known toxic compounds. Dissolved oxygen concentration, a measure of respiration, was measured with an oxygen sensor optode immobilized in the centre of each well. The cells were maintained in the dishes during the assay period and can afterwards be processed for further analyses. This dynamic, non-invasive measurement allowed calculation of 50% lethal concentrations (LC(50)) for any incubation time point giving concentration-time-dependent responses without further manipulation or removal of the cells from the incubator. Toxicokinetic profiles are compared with Sulforhodamine B assay, a common cytotoxicity assay. The novel assay is robust and flexible, very easy to carry out and provides continuous online respiration data reflecting dynamic toxicity responses. It can be adapted to any cell-based system and the calculated kinetics contributes to understanding of cell death mechanisms. [less ▲] Detailed reference viewed: 80 (0 UL) |
||