![]() ; ; et al in Engineering Structures (2020) Steel tube confined concrete (STCC) is widely used in the vertical members of high-rise buildings such as columns. The axial load is not directly resisted by the steel tube in STCC, but is resisted via ... [more ▼] Steel tube confined concrete (STCC) is widely used in the vertical members of high-rise buildings such as columns. The axial load is not directly resisted by the steel tube in STCC, but is resisted via the interfacial frictional stress between steel tube and concrete core, which is different with that of concrete filled steel tube (CFT) members and would effectively suppress the outward local buckling of steel tube at early stage. Recently, fibre-reinforced polymer (FRP) confined STCC presents a potential to enhance the ductility and durability of such vertical elements. This paper presents an experimental study on monotonic axial compressive behaviour of carbon FRP (CFRP) confined STCC (CFRP- STCC) stub column and an analytical study on the confinement mechanism of and the ultimate axial bearing capacity of the elements. A three-stage confinement mechanism involving the different contributions of the steel tube and the CFRP wrap in CFRP-STCC elements was proposed based on the test results. A prediction model of the ultimate axial bearing capacity of CFRP-STCC stub columns was developed subsequently. Results show that the presence of CFRP wrap enhances effectively the load-bearing capacity and the ductility of steel tube confined plain concrete and reinforced concrete elements, and significantly prevents the local buckling of the steel tubes in the elements. The proposed prediction model of ultimate axial bearing capacity assesses test results with a great agreement. [less ▲] Detailed reference viewed: 83 (5 UL)![]() ; ; Waldmann, Danièle ![]() in Journal of Structural Engineering (2019) This paper studies experimentally the behaviour of circular FRP-steel-confined columns subjected to reversed cyclic loads. The influence of main structural factors on the cyclic behaviour of the columns ... [more ▼] This paper studies experimentally the behaviour of circular FRP-steel-confined columns subjected to reversed cyclic loads. The influence of main structural factors on the cyclic behaviour of the columns is discussed. Test results show the outstanding seismic performance of FRP-steel confined reinforced concrete (RC) and steel-reinforced concrete (SRC) column. The lateral confinement effectiveness of FRP materials is verified in the steel tube confined RC columns. A simplified finite element method (FEM) model supported by OpenSees is developed to simulate the experimental results of the test columns. Based on the proposed FEM model, a parametric analysis is conducted for investigating the effects of several main factors on the reversed cyclic behaviour of GFRP-steel confined RC columns. Based on the test and numerical analyses, the study discusses the influence of variables such as the lateral confinement on the plastic hinge region and peak drift ratio of the studied concrete columns under reversed cyclic loads. Results indicate that the lateral confinement significantly affects the height of plastic hinge region of circular confined columns without H-steel. Based on the analysies of test data from the study and literature, the paper suggests a simple model to predict the peak drift ratio of the confined RC columns. [less ▲] Detailed reference viewed: 171 (19 UL)![]() ; ; et al in Polymers (2018) In this study, conductive carbon nanofibers (CNFs) were dispersed into epoxy resin and then infused into glass fiber fabric to fabricate CNF/glass fiber-reinforced polymer (GFRP) laminates. The electrical ... [more ▼] In this study, conductive carbon nanofibers (CNFs) were dispersed into epoxy resin and then infused into glass fiber fabric to fabricate CNF/glass fiber-reinforced polymer (GFRP) laminates. The electrical resistance and strain of CNF/GFRP laminates were measured simultaneously during tensile loadings to investigate the in situ strain and damage monitoring capability of CNF/GFRP laminates. The damage evolution and conduction mechanisms of the laminates were also presented. The results indicated that the percolation threshold of CNFs content for CNF/GFRP laminates was 0.86 wt % based on a typical power law. The resistance response during monotonic tensile loading could be classified into three stages corresponding to different damage mechanisms, which demonstrated a good ability of in situ damage monitoring of the CNF/GFRP laminates. In addition, the capacity of in situ strain monitoring of the laminates during small strain stages was also confirmed according to the synchronous and reversible resistance responses to strain under constant cyclic tensile loading. Moreover, the analysis of the resistance responses during incremental amplitude cyclic tensile loading with the maximum strain of 1.5% suggested that in situ strain and damage monitoring of the CNF/GFRP laminates were feasible and stable. [less ▲] Detailed reference viewed: 42 (5 UL)![]() ; ; et al in Construction and Building Materials (2018) Detailed reference viewed: 227 (23 UL) |
||