See detailFull scale BWR containment loca response test at the INKA test facility
Wagner, T.; Leyer, Stephan UL

in International Conference on Nuclear Engineering, Proceedings, ICONE (2015), 2015-January

KERENA is an innovative boiling water reactor concept with passive safety systems (Generation III+) of AREVA. The reactor is an evolutionary design of operating BWRs (Generation II). In order to verify ... [more ▼]

KERENA is an innovative boiling water reactor concept with passive safety systems (Generation III+) of AREVA. The reactor is an evolutionary design of operating BWRs (Generation II). In order to verify the functionality and performance of the KERENA safety concept required for the transient and accident management, the test facility "Integral Teststand Karlstein" (INKA) was built at Karlstein (Germany). It is a mock-up of the KERENA boiling water reactor containment, with integrated pressure suppression system. The complete chain of passive safety components is available. The passive components and the levels are represented in full scale. The volume scaling of the containment compartments is approximately 1:24. The reactor pressure vessel (RPV) is simulated via the steam accumulator of the Karlstein Large Valve Test Facility. This vessel provides an energy storage capacity of approximately 1/6 of the KERENA RPV and is supplied by a Benson boiler with a thermal power of 22 MW. With respect to the available power supply, the containment- and system-sizing of the facility is by far the largest one of its kind worldwide. From 2009 to 2012, several single component tests were conducted (Emergency Condenser, Containment Cooling Condenser, Core Flooding System etc.). On March 21st, 2013, the worldwide first large-scale only passively managed integral accident test of a boiling water reactor was simulated at INKA. The integral test measured the combined response of the KERENA passive safety systems to the postulated initiating event was the "Main Steam Line Break" (MSLB) inside the Containment with decay heat simulation. The results of the performed integral test (MSLB) showed that the passive safety systems alone are capable to bring the plant to stable conditions meeting all required safety targets with sufficient margins. Therefore the test verified the function of those components and the interplay between them as response to an anticipated accident scenario. The test provided evidence that the INKA is worldwide the first large scale test facility to perform integral verification tests of passive safety concepts under plant-like scaling and thermodynamic conditions. Hence, the test facility also shows that it is capable to perform containment response tests for existing Generation II BWRs (with active safety systems) and advanced (passive) reactor designs besides KERENA. These test results can be used to strengthen existing containment codes with regard to heat transfer, natural circulation, gas- and temperature stratification and others. Copyright © 2015 by JSME. [less ▲]

Detailed reference viewed: 270 (14 UL)
See detailPassive integral LOCA accident testing at Karlstein test facility
Drescher, R.; Wagner, T.; Prasser, H.-M. et al

in International Congress on Advances in Nuclear Power Plants, ICAPP 2014 (2014), 3

KERENA is an innovative boiling water reactor concept with passive safety systems (Generation III+) of AREVA . In order to verify the functionality and performance of the concept required for the ... [more ▼]

KERENA is an innovative boiling water reactor concept with passive safety systems (Generation III+) of AREVA . In order to verify the functionality and performance of the concept required for the transient and accident management, the test facility "Integral Teststand Karlstein" (INKA) was built in Karlstein (Germany). It is a mockup of the KERENA boiling water reactor containment, with integrated pressure suppression system. The complete chain of passive safety components is available. While the scaling of the passive components and the levels match the original values, the volume scaling of the containment compartments is approximately 1:24. The reactor pressure vessel (RPV) is simulated via the steam accumulator of the Karlstein Large Valve Test Facility (GAP). This vessel provides an energy storage capacity of approximately 1/6 of the KERENA RPV and is supplied by a Benson boiler with a thermal power of 22 MW. With respect to the available power supply, the containment- and system-sizing of the facility is by far the largest one of its kind worldwide. On March 21, 2013 the worldwide first large-scale, only passively managed, integral accident test of a boiling water reactor was simulated at INKA. The integral test measured the combined response of the KERENA passive safety systems to the postulated initiating event "Main Steam Line Break" (MSLB) inside the Containment with decay heat simulation. The main goals were to show the performance and the interaction of the KERENA passive safety systems, the ability to keep the core covered, to discharge the decay heat via the appropriate pathway under all circumstances and to maintain the containment within defined limits, i.e. to bring the plant to a controlled state. The performed integral test (MSLB) was being initiated via the opening of the leak at original RPV boundary conditions (75 bar reactor pressure). The leak causes a mass and energy flow from the reactor pressure vessel into the containment. The resulting drop in the RPV water level activates the Emergency Condenser, so that an additional path for energy transfer out of the RPV in parallel to the leak is opened. The pressure increase in the containment is limited via the containment pressure suppression system (short term) and the containment cooling condensers (long term). The results of the test showed that the passive safety systems alone are capable to bring the plant to stable conditions meeting all required safety targets with sufficient margins. Therefore the test verified the function of those components and the interplay between them as response to an anticipated accident scenario. The test provided evidence that the INKA is worldwide the first large scale test facility to perform integral verification tests of passive safety concepts under plant-like scaling and thermodynamic conditions. [less ▲]

Detailed reference viewed: 181 (9 UL)
See detailStatus of the full scale component testing of the KERENA ™ emergency condenser and Containment Cooling Condenser
Leyer, Stephan UL; Maisberger, F.; Herbst, V. et al

in International Congress on Advances in Nuclear Power Plants 2010, ICAPP 2010 (2010), 2

KERENA™ (SWR1000) is an innovative boiling water reactor concept with passive safety systems. In order to verify the functionality of the passive components requiredfor the transient and accident ... [more ▼]

KERENA™ (SWR1000) is an innovative boiling water reactor concept with passive safety systems. In order to verify the functionality of the passive components requiredfor the transient and accident management, the test facility INKA (Integral-Versuchstand Karlstein) is build in Karlstein (Germany). The key elements of the KERENA™ passive safety concept -the Emergency Condenser, the Containment Cooling Condenser, the Passive Core Flooding System and the Passive Pressure Pulse Transmitter - will be tested at INKA. The Emergency Condenser system transfer heaty form the reactor pressure vessel to the core flooding pools of the containment. The heat introduced into the containment during accidents will be transferred to the main heat sink for passive accident management (Shielding/Storage Pool) via the Containment Cooling Condensers. Therefore both systems are part of the passive cooling chain connecting the heat source RPV (Reactor Pressure Vessel) with the heat sink. At the INKA test facility both condensers are tested in full scale setup, in order to determine the heat transfer capacity as function of the main input parameters. For the EC these are the RPV pressure, the RPV water level, the containment pressure and the water temperature of the flooding pools. For the Containment Cooling Condenser the heat transfer capacity is a function of the containment pressure, the water temperature of the Shielding/Storage Pooland the fraction of non -condensable gases in the containment. The status of the test program and the available test data will be presented. An outlook of the future test of the passive core flooding system and the integral system test including also the passive pressure pulse transmitter will be given. [less ▲]

Detailed reference viewed: 149 (10 UL)