![]() ; Odenbreit, Christoph ![]() in Structures (2022), 44 Structural elements of building have to meet a multitude of requirements. Besides the static load bearing capacity, common requirements are the structural integrity and efficiency during the construction ... [more ▼] Structural elements of building have to meet a multitude of requirements. Besides the static load bearing capacity, common requirements are the structural integrity and efficiency during the construction stage and sufficient fire resistance. Within the French CIFRE research project COMINO, an innovative type of composite beam was developed for buildings beams with a span of 6 -12m, which need fire resistance until 2 hours with no additional supports at construction stage. The developed solution is composed of a steel U-section acting as a formwork in construction stage for a reinforced concrete part that provides the fire resistance. In the exploitation stage, the steel and the reinforced concrete are acting together as a composite beam. In construction stage, when the concrete is not hardened and thus the stabilizing effect is not present, the steel beam, is subjected to Lateral-Torsional Buckling. In order to investigate the structural behaviour of the new developed steel section in construction stage, a single full-scale test has been carried out at the Laboratory of Structural Engineering of the University of Luxembourg. This article focuses on the stability of the steel beam made of thin-walled steel parts without considering any stabilizing effect. The test results are then compared to the results of numerical investigations and to the analytical solutions of EN 1993. [less ▲] Detailed reference viewed: 25 (1 UL)![]() ; ; et al in Revue construction métallique (2021), 1 Pour conquérir de nouvelles parts de marché ou simplement défendre ses positions sur un marché très concurrentiel, il faut sans cesse améliorer la compétitivité des procédés constructifs utilisés. La ... [more ▼] Pour conquérir de nouvelles parts de marché ou simplement défendre ses positions sur un marché très concurrentiel, il faut sans cesse améliorer la compétitivité des procédés constructifs utilisés. La prise en compte de la réglementation incendie s’avère avoir une grande influence sur les matériaux constructifs et peut remettre en cause certains avantages de la filière métallique. Les solutions mixtes acier-béton constituent un très bon compromis, permettant d’optimiser la consommation des matériaux, de réduire les temps de montage tout en répondant aux exigences réglementaires en matière de sécurité incendie même les plus contraignantes notamment pour des établissements recevant du public (ERP), des sites sensibles ou encore des immeubles de grande hauteur (IGH). [less ▲] Detailed reference viewed: 69 (5 UL)![]() ; Odenbreit, Christoph ![]() in Steel and Composite Structures (2020), 34(3), 441--452 Within the French CIFRE research project COMINO, an innovative type of composite beam was developed for buildings that need fire resistance with no additional supports in construction stage. The developed ... [more ▼] Within the French CIFRE research project COMINO, an innovative type of composite beam was developed for buildings that need fire resistance with no additional supports in construction stage. The developed solution is composed of a steel U-shaped beam acting as a formwork in construction stage for a reinforced concrete part that provides the fire resistance. In the exploitation stage, the steel and the reinforced concrete are acting together as a composite beam. This paper presents the investigation made on the load bearing capacity of this new developed steel-concrete composite section. A full-scale test has been carried out at the Laboratory of Structural Engineering of the University of Luxembourg. The paper presents the configuration of the specimen, the fabrication process and the obtained test results. The beam behaved compositely and exhibited high ductility and bending resistance. The shear connection in the tension zone was effective. The beam failed by a separation between the slab and the beam at high deformations, excessive shear forces conducted to a failure of the stirrups in this zone. The test results are then compared with good agreement to analytical methods of design based on EN 1994 and design guidelines are given. [less ▲] Detailed reference viewed: 84 (3 UL) |
||