See detailArtificial intelligence and machine learning: an introduction for orthopaedic surgeons
Ley, Christophe UL; Martin, R. Kyle; Pareek, Ayoosh et al

in Knee Surgery, Sports Traumatology, Arthroscopy (2021)

The application of artificial intelligence (AI) and machine learning to the field of orthopaedic surgery is rapidly increasing. While this represents an important step in the advancement of our specialty ... [more ▼]

The application of artificial intelligence (AI) and machine learning to the field of orthopaedic surgery is rapidly increasing. While this represents an important step in the advancement of our specialty, the concept of AI is rich with statistical jargon and techniques unfamiliar to many clinicians. This knowledge gap may limit the impact and potential of these novel techniques. We aim to narrow this gap in a way that is accessible for all orthopaedic surgeons. With this manuscript, we introduce the concept of AI and machine learning and give examples of how it can impact clinical practice and patient care. [less ▲]

Detailed reference viewed: 21 (0 UL)
Full Text
Peer Reviewed
See detailMechanical strength of a new plate compared to six previously tested opening wedge high tibial osteotomy implants
Diffo Kaze, Arnaud; Maas, Stefan UL; Belsey, James et al

in Journal of Experimental Orthopaedics (2019)

Background This study aimed to assess the mechanical static and fatigue strength provided by the FlexitSystem plate in medial opening wedge high tibial osteotomies (MOWHTO), and to compare it to six ... [more ▼]

Background This study aimed to assess the mechanical static and fatigue strength provided by the FlexitSystem plate in medial opening wedge high tibial osteotomies (MOWHTO), and to compare it to six previously tested implants: the TomoFix small stature, the TomoFix standard, the ContourLock, the iBalance, the second generation PEEKPower and the size 2 Activmotion. Thus, this will provide surgeons with data that will help in the choice of the most appropriate implant for MOWHTO. Methods Six fourth-generation tibial bone composites underwent a MOWHTO and each was fixed using six FlexitSystem plates, according to standard techniques. The same testing procedure that has already been previously defined, used and published, was used to investigate the static and dynamic strength of the prepared bone-implant constructs. The test consisted of static loading and cyclical loading for fatigue testing. Results During static testing, the group constituted by the FlexitSystem showed a fracture load higher than the physiological loading of slow walking (3.7 kN > 2.4 kN). Although this fracture load was relatively small compared to the average values for the other Implants from our previous studies, except for the TomoFix small stature and the Contour Lock. During fatigue testing, FlexitSystem group showed the smallest stiffness and higher lifespan than the TomoFix and the PEEKPower groups. Conclusions The FlexitSystem plate showed sufficient strength for static loading, and average fatigue strength compared to the previously tested implants. Full body dynamic loading of the tibia after MOWHTO with the investigated implants should be avoided for at least three weeks. Implants with a wider T-shaped proximal end, positioned onto the anteromedial side of the tibia head, or inserted in the osteotomy opening in a closed-wedge construction, provided higher mechanical strength than implants with small a T-shaped proximal end, centred onto the medial side of the tibia head. [less ▲]