![]() ; ; et al in Frontiers in physiology (2013), 4 Background: Ventricular tachyarrhythmias are the most common and often the first manifestation of coronary heart disease and lead to sudden cardiac death (SCD). Early detection/identification of acute ... [more ▼] Background: Ventricular tachyarrhythmias are the most common and often the first manifestation of coronary heart disease and lead to sudden cardiac death (SCD). Early detection/identification of acute myocardial ischaemic injury at risk for malignant ventricular arrhythmias in patients remains an unmet medical need. In the present study, we examined the sphingolipids level after transient cardiac ischaemia following temporary coronary artery occlusion during percutaneous coronary intervention (PCI) in patients and determined the role of sphingolipids level as a novel marker for early detection of human myocardial ischaemic injury. Methods and Results: Venous samples were collected from either the coronary sinus (n = 7) or femoral vein (n = 24) from 31 patients aged 40-73 years-old at 1, 5 min, and 12 h, following elective PCI. Plasma sphingolipids levels were assessed by HPLC. At 1 min coronary sinus levels of sphingosine 1-phosphate (S1P), sphingosine (SPH), and sphinganine (SA) were increased by 314, 115, and 614%, respectively (n = 7), while peripheral blood levels increased by 79, 68, and 272% (n = 24). By 5 min, coronary sinus S1P and SPH levels increased further (720%, 117%), as did peripheral levels of S1P alone (792%). Where troponin T was detectable at 12 h (10 of 31), a strong correlation was found with peak S1P (R (2) = 0.818; P < 0.0001). Conclusion: For the first time, we demonstrate the behavior of plasma sphingolipids following transient cardiac ischaemia in humans. The observation supports the important role of sphingolipids level as a potential novel marker of transient or prolonged myocardial ischaemia. [less ▲] Detailed reference viewed: 171 (1 UL)![]() ; ; et al in EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology (2012), 7(10), 1170-80 AIMS: The Sideguard(R) stent (Cappella Medical Devices Ltd, Galway, Ireland), is a novel nitinol self-expanding dedicated bifurcation stent that flares proximally at the ostium of the side branch (SB ... [more ▼] AIMS: The Sideguard(R) stent (Cappella Medical Devices Ltd, Galway, Ireland), is a novel nitinol self-expanding dedicated bifurcation stent that flares proximally at the ostium of the side branch (SB) into a trumpet shape thereby achieving full ostial coverage. The aim of this study is to report the utility and limitations of this stent in patients undergoing treatment to bifurcation coronary lesions in a real-world setting. METHODS AND RESULTS: We prospectively identified 20 successive patients admitted over a 6-month period in whom there was significant SB disease and who were suitable for a bifurcation procedure. The Sideguard(R) stent was successfully used in all 20 cases including several that would have been technically difficult using conventional bifurcation techniques. We highlight use of this system using five illustrative cases that illustrate its utility and limitations in the treatment of bifurcation lesions. CONCLUSIONS: The Sideguard(R) stent can be used to treat complex bifurcation lesions in a straight forward manner and is not subject to the limitations associated with conventional bifurcation PCI techniques including jailing of the SB ostium and inability to fully cover/scaffold the ostium of the SB. [less ▲] Detailed reference viewed: 122 (1 UL)![]() ; ; et al in Journal of interventional cardiology (2011), 24(2), 172-80 AIMS: Studies demonstrate that percutaneous coronary intervention (PCI) with drug-eluting stents (DES) is associated with reduced revascularization and major adverse cardiac events (MACE) rates compared ... [more ▼] AIMS: Studies demonstrate that percutaneous coronary intervention (PCI) with drug-eluting stents (DES) is associated with reduced revascularization and major adverse cardiac events (MACE) rates compared to bare metal stents (BMS) in native coronary vessels. Optimal PCI treatment of saphenous vein graft (SVG) lesions remains unclear despite SVG procedures representing up to 10% of PCI cases. We therefore performed a meta-analysis to compare outcomes between BMS and DES in SVG PCI. METHODS AND RESULTS: A search (2004-2009) of MEDLINE and conference proceedings for all relevant studies comparing mortality and MACE outcomes in DES versus BMS in SVG PCI and meta-analysis of the data was performed. Twenty studies were identified from 2005 to 2009 enrolling a total of 5,296 patients. Meta-analysis revealed a decrease in mortality associated with DES use, odds ratio (OR) 0.68; 95% confidence interval (CI) 0.53-0.88; P = 0.004. Similarly, MACE (OR 0.64; 95% CI 0.51-0.82; P < 0.001), total lesion revascularization (OR 0.60; 95% CI 0.43-0.83; P = 0.002), and total vessel revascularization (OR 0.57; 95% CI 0.41-0.80; P = 0.001) were significantly decreased in the patients in which DES were used compared to BMS. This reduction in mortality and MACE events associated with DES use appears to be limited to registry studies and not randomized controlled studies. CONCLUSIONS: Our meta-analysis suggests DES use to be safe in SVG PCI and associated with reduced mortality and MACE rates with reductions in revascularization also observed. [less ▲] Detailed reference viewed: 148 (0 UL)![]() ; ; et al in EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology (2011), 6(8), 985-91 AIMS: PCI with drug eluting stents (DES) has been shown to reduce restenosis and major adverse cardiac event (MACE) rates compared to bare metal stents (BMS) in native coronary vessels, although outcomes ... [more ▼] AIMS: PCI with drug eluting stents (DES) has been shown to reduce restenosis and major adverse cardiac event (MACE) rates compared to bare metal stents (BMS) in native coronary vessels, although outcomes in saphenous vein graft (SVG) lesions are less clear. We retrospectively studied 388 consecutive patients admitted to our centre for SVG PCI to assess mortality and MACE outcomes (defined as composite endpoint of all-death, stroke, myocardial infarction, stent thrombosis and target lesion (TLR)/vessel (TVR) revascularisation) associated with BMS and DES use. METHODS AND RESULTS: Two hundred and nineteen (219) patients had BMS and 169 had DES (total 388 patients). Mean follow up was 41.9+/-23.5 months. No significant differences were observed in mortality (14.2% vs. 11.8%) or MACE (37.6% vs. 35.8%) between the BMS and DES groups at four years follow-up or at other intervening time points studied. Similarly, no differences in TVR/TLR rates were observed over a similar time period (19.8% vs. 21.6%). CONCLUSIONS: We have observed that DES and BMS use in SVG PCI have comparable mortality and MACE rates, and that in contrast to PCI in native coronary arteries, DES do not reduce revascularisation rates in our study cohort. [less ▲] Detailed reference viewed: 143 (0 UL)![]() ; ; et al in Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions (2010), 75(4), 596-602 OBJECTIVE: The aim of this study is to investigate the feasibility of using a 6.5 Fr sheathless guide catheter as a default system in transradial (TRA) percutaneous coronary intervention (PCI). BACKGROUND ... [more ▼] OBJECTIVE: The aim of this study is to investigate the feasibility of using a 6.5 Fr sheathless guide catheter as a default system in transradial (TRA) percutaneous coronary intervention (PCI). BACKGROUND: TRA PCI has been shown to reduce mortality rates through a reduction in access site related bleeding complications compared with procedures performed though a femoral approach. Complications associated with the TRA route increase with the size of sheath used. These complications may be reduced by the use of a sheathless guide catheter system (Asahi Intecc, Japan) that is 1-2 Fr sizes smaller in diameter than the corresponding introducer sheath. METHODS: We performed PCI in 100 consecutive cases using 6.5 Fr sheathless guides to determine the procedural success, rates of symptomatic radial spasm and radial occlusion. RESULTS: Procedural success using the 6.5 Fr sheathless guide catheter system was 100% with no cases requiring conversion to a conventional guide and catheter system. There were no procedural complications recorded associated with the use of the catheter. Adjunctive devices used in this cohort included IVUS, stent delivery catheters, distal protection devices, and simple thrombectomy catheters. The rate of radial spasm was 5% and the rate of radial occlusion at 2 months was 2%. CONCLUSION: Use of the 6.5 Fr sheathless guide catheter system, which has an outer diameter <5 Fr sheath, as the default system in routine PCI is feasible with a high rate of procedural success via the radial artery. [less ▲] Detailed reference viewed: 139 (0 UL)![]() ; ; et al in The Journal of invasive cardiology (2010), 22(6), 260-5 OBJECTIVE: To investigate the relationship between resting distal coronary pressure to aortic pressure ratio (Pd/Pa) and fractional flow reserve (FFR) obtained during maximal hyperemia. BACKGROUND: FFR is ... [more ▼] OBJECTIVE: To investigate the relationship between resting distal coronary pressure to aortic pressure ratio (Pd/Pa) and fractional flow reserve (FFR) obtained during maximal hyperemia. BACKGROUND: FFR is an invasive index of the functional severity of a coronary artery stenosis determined from coronary pressure measurements. It is generally believed that there is little correlation between resting Pd/Pa and FFR obtained during maximal hyperemia. We have therefore studied this relationship in a large cohort of patients who had undergone pressure- wire assessments. METHODS: 528 consecutive pressure-wire studies performed in 483 patients over a 2-year period were retrospectively analyzed. RESULTS: A linear correlation between resting Pd/Pa and FFR post-pharmacological hyperemia was observed (rho = 0.74; p < 0.0001). When a FFR of < or = 0.75 (or < or = 0.80 as per FAME) was defined as positive, a resting Pd/Pa of < or = 0.85 (< or = 0.87) had a positive predictive value (PPV) of 95% (94.6%), while a resting Pd/Pa of > or = 0.93 (> or = 0.96) had a negative predictive value (NPV) of 95.7% (93%). CONCLUSIONS: We demonstrate a strong correlation between resting Pd/Pa and FFR. Resting values of Pd/Pa can be used to predict a positive FFR result with relatively high PPV and NPV. This may potentially obviate the need for adenosine infusion in a proportion of pressure-wire studies. [less ▲] Detailed reference viewed: 88 (0 UL)![]() ; ; et al in EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology (2009), 5(2), 265-71 AIMS: The Terumo Heartrail catheter (Terumo Corp., Tokyo, Japan) allows extra deep catheter intubation of coronary vessels and has been shown to be useful in CTO lesions. The aim of this study is to ... [more ▼] AIMS: The Terumo Heartrail catheter (Terumo Corp., Tokyo, Japan) allows extra deep catheter intubation of coronary vessels and has been shown to be useful in CTO lesions. The aim of this study is to assess the safety and efficacy of using the Heartrail II catheter as a distal stent delivery system in PCI following failure of conventional techniques. METHODS AND RESULTS: We prospectively identified cases performed over a 15-month period in which a Heartrail catheter was used to facilitate stent delivery following failure of conventional techniques. Stent delivery using the Heartrail catheter was performed in 35 cases and was successful in 31 cases. Success rates of 100% in grafts, 95% in RCA, 80% in LAD and 60% in circumflex cases were recorded respectively. Successful stent delivery was associated with intubation depth, with 29/29 succeeding when the intubation depth was > 2 cm and failure in 4/5 cases when the intubation depth <or= 2 cm. There were no complications related to deep intubation of the catheter. CONCLUSIONS: Use of the Heartrail catheter is safe and highly effective for aiding stent delivery across proximal obstructions in both left and right coronary systems. The small number of unsuccessful cases were related to inability of the catheter to traverse stenotic proximal obstructions within 2 cm of the RCA and LCA origins. [less ▲] Detailed reference viewed: 128 (0 UL) |
||